DMU-03

DMG MORI DMU 50 (3rd Generation) · Siemens SINUMERIK ONE · Bay 1 · Cell C · s/n DMU50-22211

Live machine view
Five-axis cycle
X/Y/Z, the swivelling B trunnion and the C rotary table follow live telemetry; the door opens when the machine stops. Drag to rotate, scroll to zoom.
Cutting
Effectiveness
OEE this shift
Late (14:00–22:00) · 119 of 134 min running
66%

Availability

89.0%

Performance

74.7%

Quality

100.0%

Current job
WO-24117
Valve block · BH-9021-D

Pieces

10 / 20

Cycle time

6m 35s

This piece

4m 34s elapsed

Operator

Sandro Pereira

Tool

T3 · Ø10 bull nose

Tool life left

95%

Finishes

17 Nov 17:04

Losses
Downtime by reason
14.7 minutes lost this shift, biggest first.

Setup / first-off

5.8 min

Tool change

2.8 min

Breakdown

1.9 min

No material

1.8 min

Waiting QA

1.4 min

No operator

1.0 min

Quality
Pieces this shift
Ideal 228 s versus actual 305 s per piece.

Good

23

Scrap

0

Rework

0

OEE per hour · %

Queue
Jobs on this machine (3)
The job on the spindle and everything queued behind it, earliest due date first.

WO-24117

Brunner Hydraulik · BH-9021-D OP30 · Al 6082 · setup 46 min

Late

10/20 · due 17 Nov 03:13

WO-24121

Sandvik Tooling · ST-3390-A OP20 · H13 tool steel · setup 35 min

Queued

0/20 · due 19 Nov 03:13

WO-24125

Hot

Helvetica Medtech · HM-2208-C OP10 · 316L stainless · setup 86 min

Queued

0/12 · due 20 Nov 03:13

Readings
Live telemetry
Polled every 5 seconds · spindle 14,433 h, service in 165 h

Spindle load

68 %

Spindle speed

8,366 rpm

Feed rate

1,457 mm/min

Spindle temp

48.9 °C

Coolant temp

27 °C

Coolant pressure

16.7 bar

Vibration

1.85 mm/s

Axis load B

28 %

Axis positions

X

-119.0

Y

-126.0

Z

-138.9

B

-59.7

C

139.4

Spindle history
Spindle load, speed and vibration

Spindle load · %

Spindle speed · rpm

Vibration · mm/s

Alarms
Alarms (8)

Door interlock opened during cycle

Alarm 6621 · 11-17 15:03

High

B axis drive temperature high

Alarm 1105 · 11-17 14:13

Medium

Tool life expired on T7, change required

Alarm 2019 · 11-17 13:51

Low

Tool life expired on T7, change required

Alarm 2019 · 11-16 14:17

High

C axis following error

Alarm 1188 · 11-16 05:22

Medium

Coolant level low in the tank

Alarm 7014 · 11-16 00:42

High

Coolant level low in the tank

Alarm 7014 · 11-15 23:55

High

Coolant level low in the tank

Alarm 7014 · 11-15 19:59

High