DMU-10

DMG MORI DMU 50 (3rd Generation) · Heidenhain TNC 640 · Bay 3 · Cell B · s/n DMU50-21252

Live machine view
Five-axis cycle
X/Y/Z, the swivelling B trunnion and the C rotary table follow live telemetry; the door opens when the machine stops. Drag to rotate, scroll to zoom.
Setup
Effectiveness
OEE this shift
Late (14:00–22:00) · 118 of 134 min running
74%

Availability

88.6%

Performance

88.4%

Quality

94.1%

Current job
WO-24187
Blade root fixture · NT-6650-A

Pieces

19 / 24

Cycle time

4m 32s

This piece

0s elapsed

Operator

Unattended

Tool

T7 · Ø6 finishing end mill

Tool life left

62%

Finishes

—

Losses
Downtime by reason
15.3 minutes lost this shift, biggest first.

Setup / first-off

5.6 min

No operator

3.0 min

Tool change

2.2 min

No material

1.7 min

Waiting QA

1.4 min

Breakdown

1.3 min

Quality
Pieces this shift
Ideal 180 s versus actual 204 s per piece.

Good

32

Scrap

1

Rework

1

OEE per hour · %

Queue
Jobs on this machine (3)
The job on the spindle and everything queued behind it, earliest due date first.

WO-24187

High

Aerodyn Systems · NT-6650-A OP20 · Inconel 718 · setup 51 min

Paused

19/24 · due 18 Nov 22:13

WO-24191

Hot

Brunner Hydraulik · RR-8834-B OP20 · Al 6061-T6 · setup 39 min

Queued

0/24 · due 20 Nov 01:13

WO-24193

Kessler Motorsport · VO-2075-A OP30 · Invar 36 · setup 57 min

Queued

0/24 · due 20 Nov 10:13

Readings
Live telemetry
Polled every 5 seconds · spindle 9,841 h, service in 830 h

Spindle load

0 %

Spindle speed

0 rpm

Feed rate

0 mm/min

Spindle temp

21 °C

Coolant temp

20.1 °C

Coolant pressure

0 bar

Vibration

0 mm/s

Axis load B

0 %

Axis positions

X

0.0

Y

0.0

Z

0.0

B

0.0

C

0.0

Spindle history
Spindle load, speed and vibration

Spindle load · %

Spindle speed · rpm

Vibration · mm/s

Alarms
Alarms (5)

Door interlock opened during cycle

Alarm 6621 · 11-16 20:43

Medium

Door interlock opened during cycle

Alarm 6621 · 11-16 14:12

Medium

Workpiece clamping pressure dropped

Alarm 9007 · 11-16 05:20

High

Spindle overload — feed hold triggered

Alarm 4073 · 11-15 23:12

High

Workpiece clamping pressure dropped

Alarm 9007 · 11-15 17:04

High