DMU-03

DMG MORI DMU 50 (3rd Generation) · Siemens SINUMERIK ONE · Bay 1 · Cell C · s/n DMU50-22211

Live machine view
Five-axis cycle
X/Y/Z, the swivelling B trunnion and the C rotary table follow live telemetry; the door opens when the machine stops. Drag to rotate, scroll to zoom.
Cutting
Effectiveness
OEE this shift
Late (14:00–22:00) · 125 of 144 min running
65%

Availability

86.9%

Performance

74.7%

Quality

100.0%

Current job
WO-24117
Valve block · BH-9021-D

Pieces

10 / 20

Cycle time

6m 35s

This piece

1m 24s elapsed

Operator

Sandro Pereira

Tool

T5 · Ø8 ball nose

Tool life left

94%

Finishes

17 Nov 17:14

Losses
Downtime by reason
18.9 minutes lost this shift, biggest first.

Setup / first-off

7.2 min

Tool change

3.7 min

No material

2.6 min

Breakdown

2.3 min

Waiting QA

1.9 min

No operator

1.2 min

Quality
Pieces this shift
Ideal 228 s versus actual 305 s per piece.

Good

24

Scrap

0

Rework

0

OEE per hour · %

Queue
Jobs on this machine (3)
The job on the spindle and everything queued behind it, earliest due date first.

WO-24117

Brunner Hydraulik · BH-9021-D OP30 · Al 6082 · setup 46 min

Late

10/20 · due 17 Nov 03:23

WO-24121

Sandvik Tooling · ST-3390-A OP20 · H13 tool steel · setup 35 min

Queued

0/20 · due 19 Nov 03:23

WO-24125

Hot

Helvetica Medtech · HM-2208-C OP10 · 316L stainless · setup 86 min

Queued

0/12 · due 20 Nov 03:23

Readings
Live telemetry
Polled every 5 seconds · spindle 14,433 h, service in 165 h

Spindle load

67 %

Spindle speed

8,388 rpm

Feed rate

1,847 mm/min

Spindle temp

49.5 °C

Coolant temp

26.8 °C

Coolant pressure

18.6 bar

Vibration

1.81 mm/s

Axis load B

18 %

Axis positions

X

36.9

Y

-124.4

Z

-176.9

B

-46.8

C

330.5

Spindle history
Spindle load, speed and vibration

Spindle load · %

Spindle speed · rpm

Vibration · mm/s

Alarms
Alarms (8)

Door interlock opened during cycle

Alarm 6621 · 11-17 15:14

High

B axis drive temperature high

Alarm 1105 · 11-17 14:23

Medium

Tool life expired on T7, change required

Alarm 2019 · 11-17 14:02

Low

Tool life expired on T7, change required

Alarm 2019 · 11-16 14:27

High

C axis following error

Alarm 1188 · 11-16 05:32

Medium

Coolant level low in the tank

Alarm 7014 · 11-16 00:52

High

Coolant level low in the tank

Alarm 7014 · 11-16 00:05

High

Coolant level low in the tank

Alarm 7014 · 11-15 20:10

High